Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Immunol ; 13: 790334, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35222375

RESUMO

The capacity of pre-existing immunity to human common coronaviruses (HCoV) to cross-protect against de novo COVID-19is yet unknown. In this work, we studied the sera of 175 COVID-19 patients, 76 healthy donors and 3 intravenous immunoglobulins (IVIG) batches. We found that most COVID-19 patients developed anti-SARS-CoV-2 IgG antibodies before IgM. Moreover, the capacity of their IgGs to react to beta-HCoV, was present in the early sera of most patients before the appearance of anti-SARS-CoV-2 IgG. This implied that a recall-type antibody response was generated. In comparison, the patients that mounted an anti-SARS-COV2 IgM response, prior to IgG responses had lower titres of anti-beta-HCoV IgG antibodies. This indicated that pre-existing immunity to beta-HCoV was conducive to the generation of memory type responses to SARS-COV-2. Finally, we also found that pre-COVID-19-era sera and IVIG cross-reacted with SARS-CoV-2 antigens without neutralising SARS-CoV-2 infectivity in vitro. Put together, these results indicate that whilst pre-existing immunity to HCoV is responsible for recall-type IgG responses to SARS-CoV-2, it does not lead to cross-protection against COVID-19.


Assuntos
Betacoronavirus/fisiologia , COVID-19/imunologia , Resfriado Comum/imunologia , Imunoglobulinas Intravenosas/uso terapêutico , SARS-CoV-2/fisiologia , Idoso , Idoso de 80 Anos ou mais , Anticorpos Neutralizantes/metabolismo , Anticorpos Antivirais/metabolismo , Antígenos Virais/imunologia , COVID-19/mortalidade , COVID-19/terapia , Reações Cruzadas , Feminino , Humanos , Imunidade Heteróloga , Imunoglobulina G/metabolismo , Imunoglobulina M/metabolismo , Memória Imunológica , Masculino , Pessoa de Meia-Idade , Análise de Sobrevida
2.
Ann Rheum Dis ; 81(4): 575-583, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34607791

RESUMO

OBJECTIVES: Our aim was to evaluate systemic lupus erythematosus (SLE) disease activity and SARS-CoV-2-specific immune responses after BNT162b2 vaccination. METHODS: In this prospective study, disease activity and clinical assessments were recorded from the first dose of vaccine until day 15 after the second dose in 126 patients with SLE. SARS-CoV-2 antibody responses were measured against wild-type spike antigen, while serum-neutralising activity was assessed against the SARS-CoV-2 historical strain and variants of concerns (VOCs). Vaccine-specific T cell responses were quantified by interferon-γ release assay after the second dose. RESULTS: BNT162b2 was well tolerated and no statistically significant variations of BILAG (British Isles Lupus Assessment Group) and SLEDAI (SLE Disease Activity Index) scores were observed throughout the study in patients with SLE with active and inactive disease at baseline. Mycophenolate mofetil (MMF) and methotrexate (MTX) treatments were associated with drastically reduced BNT162b2 antibody response (ß=-78, p=0.007; ß=-122, p<0.001, respectively). Anti-spike antibody response was positively associated with baseline total immunoglobulin G serum levels, naïve B cell frequencies (ß=2, p=0.018; ß=2.5, p=0.003) and SARS-CoV-2-specific T cell response (r=0.462, p=0.003). In responders, serum neutralisation activity decreased against VOCs bearing the E484K mutation but remained detectable in a majority of patients. CONCLUSION: MMF, MTX and poor baseline humoral immune status, particularly low naïve B cell frequencies, are independently associated with impaired BNT162b2 mRNA antibody response, delineating patients with SLE who might need adapted vaccine regimens and follow-up.


Assuntos
Antirreumáticos/efeitos adversos , Vacina BNT162/imunologia , Imunidade Humoral/efeitos dos fármacos , Lúpus Eritematoso Sistêmico/imunologia , SARS-CoV-2/imunologia , Adulto , Anticorpos Antivirais/imunologia , Antirreumáticos/imunologia , COVID-19/prevenção & controle , Feminino , Humanos , Imunogenicidade da Vacina/efeitos dos fármacos , Lúpus Eritematoso Sistêmico/tratamento farmacológico , Lúpus Eritematoso Sistêmico/virologia , Masculino , Metotrexato/efeitos adversos , Metotrexato/imunologia , Pessoa de Meia-Idade , Ácido Micofenólico/efeitos adversos , Ácido Micofenólico/imunologia , Estudos Prospectivos , Índice de Gravidade de Doença
3.
Sci Transl Med ; 13(577)2021 01 20.
Artigo em Inglês | MEDLINE | ID: mdl-33288662

RESUMO

Humoral immune responses are typically characterized by primary IgM antibody responses followed by secondary antibody responses associated with immune memory and composed of IgG, IgA, and IgE. Here, we measured acute humoral responses to SARS-CoV-2, including the frequency of antibody-secreting cells and the presence of SARS-CoV-2-specific neutralizing antibodies in the serum, saliva, and bronchoalveolar fluid of 159 patients with COVID-19. Early SARS-CoV-2-specific humoral responses were dominated by IgA antibodies. Peripheral expansion of IgA plasmablasts with mucosal homing potential was detected shortly after the onset of symptoms and peaked during the third week of the disease. The virus-specific antibody responses included IgG, IgM, and IgA, but IgA contributed to virus neutralization to a greater extent compared with IgG. Specific IgA serum concentrations decreased notably 1 month after the onset of symptoms, but neutralizing IgA remained detectable in saliva for a longer time (days 49 to 73 post-symptoms). These results represent a critical observation given the emerging information as to the types of antibodies associated with optimal protection against reinfection and whether vaccine regimens should consider targeting a potent but potentially short-lived IgA response.


Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , COVID-19/diagnóstico , Imunidade Humoral , Imunoglobulina A/sangue , SARS-CoV-2/imunologia , Biomarcadores/sangue , Líquido da Lavagem Broncoalveolar/imunologia , Líquido da Lavagem Broncoalveolar/virologia , COVID-19/sangue , COVID-19/imunologia , COVID-19/virologia , Estudos de Casos e Controles , Interações Hospedeiro-Patógeno , Humanos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Estudos Longitudinais , Saliva/imunologia , Saliva/virologia , Fatores de Tempo
4.
Rheumatology (Oxford) ; 59(8): 1927-1937, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-31755959

RESUMO

OBJECTIVES: JDM and juvenile overlap myositis represent heterogeneous subtypes of juvenile idiopathic inflammatory myopathy (JIIM). Chronic evolution can occur in up to 60% of cases, and morbidity/mortality is substantial. We aimed to describe the clinical, biological, histological and type I IFN status in JIIM associated with anti-melanoma differentiation-associated protein 5 (anti-MDA5) autoantibodies at presentation (group 1) in comparison with other JIIM (group 2). METHODS: This was a retrospective and prospective study of patients with JIIM ascertained from three French paediatric rheumatology reference centres between 2013 and 2019. Muscle biopsies were reviewed. Type I interferon pathway activity was assessed by dosage of IFNα serum protein and the expression of IFN-stimulated genes. RESULTS: Sixty-four patients were included, 13 in group 1 (54% JDM and 46% juvenile overlap myositis) and 51 in group 2 (76% JDM and 24% juvenile overlap myositis). Group 1 patients demonstrated more arthritis, skin ulcerations, lupus features and interstitial lung disease, and a milder muscular involvement. Serum IFNα levels were higher in group 1 than 2, and decreased after treatment or improvement in both groups. Outcome was similar in both groups. Unconventional treatment (more than two lines) was required in order to achieve remission, especially when skin ulceration was reported. CONCLUSION: This study indicates a higher frequency of arthritis, skin ulcerations and interstitial lung disease, but milder muscular involvement, in JIIM with positive anti-MDA5 autoantibodies compared with other JIIM. Our data support an important role of systemic IFNα in disease pathology, particularly in the anti-MDA5 auto-antibody-positive subgroup. In severe and refractory forms of JIIM, IFNα may represent a therapeutic target.


Assuntos
Autoanticorpos/imunologia , Helicase IFIH1 Induzida por Interferon/imunologia , Interferon-alfa/metabolismo , Músculo Esquelético/metabolismo , Miosite/metabolismo , Transdução de Sinais/fisiologia , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Músculo Esquelético/imunologia , Músculo Esquelético/patologia , Miosite/imunologia , Miosite/patologia , Estudos Prospectivos , Estudos Retrospectivos
5.
PLoS One ; 13(8): e0202736, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30161159

RESUMO

A novel technology, photonic ring immunoassay (PRI), for detecting 12 autoantibodies simultaneously in whole blood in less than 15 minutes was evaluated by comparing results from 235 clinically diagnosed patients with standard laboratory tests. The overall agreement was greater than 91% for 10 of the 12 assays, with positive percent agreement greater than 89% for 9 of the assays and negative percent agreement greater than 91% for 10 of them. Thus, the clinical sensitivities and specificities were similar for the 2 methods. In addition, 199 normal blood donors were tested on the ANA 12 PRI, yielding specificities greater than 97.5% for all assays. This proof of concept study shows that this new system is suitable for point of care testing for clinically useful autoantibodies, allowing the doctor to have test results in minutes rather than days.


Assuntos
Autoanticorpos/sangue , Doenças do Tecido Conjuntivo/diagnóstico , Imunoensaio/métodos , Doadores de Sangue , Humanos , Laboratórios , Sensibilidade e Especificidade
6.
J Immunol Methods ; 448: 34-43, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28527901

RESUMO

Photonic ring resonance is a property of light where in certain circumstances specific wavelengths are trapped in a ring resonator. Sensors based on silicon photonic ring resonators function by detecting the interaction between light circulating inside the sensor and matter deposited on the sensor surface. Binding of biological material results in a localized change in refractive index on the sensor surface, which affects the circulating optical field extending beyond the sensor boundary. That is, the resonant wavelength will change when the refractive index of the medium around the ring resonator changes. Ring resonators can be fabricated onto small silicon chips, allowing development of a miniature multiplex array of ring based biosensors. This paper describes the properties of such a system when responding to the refractive index changed in a simple and precise way by changing the ionic strength of the surrounding media, and in a more useful way by the binding of macromolecules to the surface above the resonators. Specifically, a capture immunoassay is described that measures the change of resonant wavelength as a patient serum sample with anti-SS-A autoantibodies is flowed over a chip spotted with SS-A antigen and amplified with anti-IgG. The technology has been miniaturized and etched into a 4×6mm silicon chip that can measure 32 different reactions in quadruplicate simultaneously. The variability between 128 rings on a chip as measured by 2M salt assays averaged 0.6% CV. The output of the assays is the average shift per cluster of 4 rings, and the assays averaged 0.5% CV between clusters. The variability between chips averaged 1.8%. Running the same array on multiple instruments showed that after some improvements to the wavelength referencing system, the upper boundary of variation was 3% between 13 different instruments. The immunoassay displayed about 2% higher variability than the salt assays. There are several outstanding features of this system. The amount of antigen used on the chip for each test is around 200 picograms, only a few microliters of sample is necessary, and the assays take <10min.


Assuntos
Anticorpos Antinucleares/sangue , Técnicas Biossensoriais/métodos , Imunoensaio/métodos , Luz , Procedimentos Analíticos em Microchip/métodos , Óptica e Fotônica/métodos , Testes Sorológicos/métodos , Biomarcadores/sangue , Técnicas Biossensoriais/instrumentação , Desenho de Equipamento , Humanos , Imunoensaio/instrumentação , Dispositivos Lab-On-A-Chip , Miniaturização , Óptica e Fotônica/instrumentação , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Testes Sorológicos/instrumentação , Silício/efeitos da radiação , Fatores de Tempo , Transdutores , Fluxo de Trabalho
7.
Clin Rev Allergy Immunol ; 41(1): 20-35, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19997988

RESUMO

Clinical multiplex diagnostic proteomics is the application of proteomic technologies to improve a patient's clinical outcomes. The future holds impact potential for testing prognosis, diagnosis, and drug therapy, while monitoring efficacious treatment with qualitative and quantitative data. Multiplex clinical diagnostic use of novel biomarkers in body fluids to confirm presence and severity of clinical disease states, holds great promise for clinical use. Challenges for diagnostic clinics include awareness of proteome complexity in clinical samples, the effects of high-abundance proteins, such as albumin, that could mask detection of other and low abundance disease proteins or biomarkers. Standardized approaches to sample collection and preparation, new analytical techniques and novel algorithms for bio-statistical analysis will facilitate release of the great potential of clinical multiplex diagnostic proteomics. A sensitive RA assay has been developed for the simultaneous measurement of the three rheumatoid factors (RFs), RF-IgA, IgG, and IgM, with the option to simultaneously measure anti-cyclic citrullinated peptide (anti-CCP) IgG antibodies using IgXPLEX™: technology. Testing 10-µL serum samples, SQI's multiplex microarray rheumatoid arthritis assay provides both positive/negative as well as qualitative/semi-quantitative results for anti-CCP IgG, RF-IgA, IgG, and IgM in each sample well on a 96-well microtiter-formatted microarray plate. Signal detection uses sensitive fluorescent-tagged markers captured onto planar microarray spots and read in a microarray scanner. Each result is verified with confidence confirmation technology and validating quality controls in every sample well. For an 80-RA positive patient cohort, the 4-PLEX profile sensitivity was determined at 82.5%. The specificity for the 44 RA healthy control cohort was determined at 97.7%. The multiplex data also demonstrated that a patients' severity of disease profile, mild to severe, correlates the status of RA biomarkers to disease status.


Assuntos
Artrite Reumatoide/diagnóstico , Testes Imunológicos , Análise em Microsséries , Adolescente , Artrite Reumatoide/imunologia , Artrite Reumatoide/fisiopatologia , Biomarcadores/sangue , Progressão da Doença , Ensaios de Triagem em Larga Escala , Humanos , Imunoglobulinas/sangue , Masculino , Microtecnologia , Pessoa de Meia-Idade , Peptídeos Cíclicos/imunologia , Prognóstico , Proteômica/instrumentação , Proteômica/métodos , Proteômica/tendências , Reprodutibilidade dos Testes , Fator Reumatoide/sangue , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...